range |
TeSys
|
|
---|---|---|
product name |
TeSys D
|
|
product or component type |
Contactor
|
|
device short name |
LC1D
|
|
contactor application |
Motor control
Resistive load |
|
utilisation category |
AC-3
AC-1 AC-4 |
|
poles description |
3P
|
|
power pole contact composition |
3 NO
|
|
[Ue] rated operational voltage |
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC |
|
[Ie] rated operational current |
18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
|
motor power kW |
4Â kW at 220…230 V AC 50/60 Hz (AC-3)
7.5Â kW at 380…400 V AC 50/60 Hz (AC-3) 9Â kW at 415…440 V AC 50/60 Hz (AC-3) 10Â kW at 500 V AC 50/60 Hz (AC-3) 10Â kW at 660…690 V AC 50/60 Hz (AC-3) 4Â kW at 400 V AC 50/60 Hz (AC-4) |
|
motor power HP (UL / CSA) |
1Â hp at 115 V AC 50/60 Hz for 1 phase motors
3Â hp at 230/240 V AC 50/60 Hz for 1 phase motors 5Â hp at 200/208 V AC 50/60 Hz for 3 phases motors 5Â hp at 230/240 V AC 50/60 Hz for 3 phases motors 10Â hp at 460/480 V AC 50/60 Hz for 3 phases motors 15Â hp at 575/600 V AC 50/60 Hz for 3 phases motors |
|
control circuit type |
AC at 50/60 Hz
|
|
[Uc] control circuit voltage |
230 V AC 50/60 Hz
|
|
auxiliary contact composition |
1 NO + 1 NC
|
|
[Uimp] rated impulse withstand voltage |
6Â kV conforming to IEC 60947
|
|
overvoltage category |
III
|
|
[Ith] conventional free air thermal current |
10 A (at 60 °C) for signalling circuit
32 A (at 60 °C) for power circuit |
|
Irms rated making capacity |
140Â A AC for signalling circuit conforming to IEC 60947-5-1
250Â A DC for signalling circuit conforming to IEC 60947-5-1 300Â A at 440 V for power circuit conforming to IEC 60947 |
|
rated breaking capacity |
300Â A at 440 V for power circuit conforming to IEC 60947
|
|
[Icw] rated short-time withstand current |
145 A 40 °C – 10 s for power circuit
240 A 40 °C – 1 s for power circuit 40 A 40 °C – 10 min for power circuit 84 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
|
associated fuse rating |
10Â A gG for signalling circuit conforming to IEC 60947-5-1
50Â A gG at <= 690 V coordination type 1 for power circuit 35Â A gG at <= 690 V coordination type 2 for power circuit |
|
average impedance |
2.5Â mOhm – Ith 32Â A 50 Hz for power circuit
|
|
[Ui] rated insulation voltage |
Power circuit: 690Â V conforming to IEC 60947-4-1
Power circuit: 600Â V CSA certified Power circuit: 600Â V UL certified Signalling circuit: 690Â V conforming to IEC 60947-1 Signalling circuit: 600Â V CSA certified Signalling circuit: 600Â V UL certified |
|
electrical durability |
1.65Â Mcycles 18Â A AC-3 at Ue <= 440 V
1Â Mcycles 32Â A AC-1 at Ue <= 440 V |
|
power dissipation per pole |
2.5Â W AC-1
0.8Â W AC-3 |
|
Front cover |
With
|
|
mounting support |
Rail
Plate |
|
standards |
CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
|
product certifications |
UL
LROS (Lloyds register of shipping) BV CSA GOST GL CCC DNV RINA |
|
connections – terminals |
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: screw clamp terminals 1 cable(s) 1.5…6 mm²flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…6 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1.5…6 mm²solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²solid without cable end |
|
tightening torque |
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 |
|
operating time |
12…22 ms closing
4…19 ms opening |
|
safety reliability level |
B10d = 1369863Â cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000Â cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
|
mechanical durability |
15Â Mcycles
|
|
maximum operating rate |
3600 cyc/h 60 °C
|
TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 230 V AC coil
22,000 CFA
Ref: LC1D18P7
SKU:
LC1D18P7
Categories: Circuit breakers, Electrical
Description
Additional information
Brand |
Schneider |
---|
Reviews (0)
Be the first to review “TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 230 V AC coil” Cancel reply
Shipping & Delivery
Reviews
There are no reviews yet.