Description
range | TeSys | |
---|---|---|
product name | TeSys D | |
product or component type | Contactor | |
device short name | LC1D | |
contactor application | Resistive load Motor control | |
utilisation category | AC-4 AC-1 AC-3 | |
poles description | 3P | |
power pole contact composition | 3 NO | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC | |
[Ie] rated operational current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit | |
motor power kW | 2.2Â kW at 220…230 V AC 50/60 Hz (AC-3) 4Â kW at 380…400 V AC 50/60 Hz (AC-3) 4Â kW at 415…440 V AC 50/60 Hz (AC-3) 5.5Â kW at 500 V AC 50/60 Hz (AC-3) 5.5Â kW at 660…690 V AC 50/60 Hz (AC-3) 2.2Â kW at 400 V AC 50/60 Hz (AC-4) | |
motor power HP (UL / CSA) | 1Â hp at 230/240 V AC 50/60 Hz for 1 phase motors 2Â hp at 200/208 V AC 50/60 Hz for 3 phases motors 2Â hp at 230/240 V AC 50/60 Hz for 3 phases motors 5Â hp at 460/480 V AC 50/60 Hz for 3 phases motors 7.5Â hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.33Â hp at 115 V AC 50/60 Hz for 1 phase motors | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 230 V AC 50/60 Hz | |
auxiliary contact composition | 1 NO + 1 NC | |
[Uimp] rated impulse withstand voltage | 6Â kV conforming to IEC 60947 | |
overvoltage category | III | |
[Ith] conventional free air thermal current | 25 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit | |
Irms rated making capacity | 250Â A at 440 V for power circuit conforming to IEC 60947 140Â A AC for signalling circuit conforming to IEC 60947-5-1 250Â A DC for signalling circuit conforming to IEC 60947-5-1 | |
rated breaking capacity | 250Â A at 440 V for power circuit conforming to IEC 60947 | |
[Icw] rated short-time withstand current | 105 A 40 °C – 10 s for power circuit 210 A 40 °C – 1 s for power circuit 30 A 40 °C – 10 min for power circuit 61 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit | |
associated fuse rating | 10Â A gG for signalling circuit conforming to IEC 60947-5-1 25Â A gG at <= 690 V coordination type 1 for power circuit 20Â A gG at <= 690 V coordination type 2 for power circuit | |
average impedance | 2.5Â mOhm – Ith 25Â A 50 Hz for power circuit | |
[Ui] rated insulation voltage | Power circuit: 690Â V conforming to IEC 60947-4-1 Power circuit: 600Â V CSA certified Power circuit: 600Â V UL certified Signalling circuit: 690Â V conforming to IEC 60947-1 Signalling circuit: 600Â V CSA certified Signalling circuit: 600Â V UL certified | |
electrical durability | 0.6Â Mcycles 25Â A AC-1 at Ue <= 440 V 2Â Mcycles 9Â A AC-3 at Ue <= 440 V | |
power dissipation per pole | 1.56Â W AC-1 0.2Â W AC-3 | |
Front cover | With | |
mounting support | Rail Plate | |
standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 | |
product certifications | GOST BV LROS (Lloyds register of shipping) DNV CSA RINA CCC UL GL | |
connections – terminals | Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end | |
tightening torque | Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 | |
operating time | 12…22 ms closing 4…19 ms opening | |
safety reliability level | B10d = 1369863Â cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000Â cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 15Â Mcycles | |
maximum operating rate | 3600 cyc/h 60 °C |
Additional information
Brand |
Schneider |
---|
Reviews (0)
Be the first to review “TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A – 230 V AC coil” Cancel reply
Shipping & Delivery
Related products
Sensor LED Spot Premium City SH 8005 PIR IP44 with PIR sensor 80×0,5W 3700lm anthracite white & black Energy efficiency class A+
75,000 CFA
Power: 40 W. Luminous flux: 3700 lm. Lamp efficacy: 93 lm/W. Colour temperature: 6000 K. Energy efficiency class: A+
Select options
This product has multiple variants. The options may be chosen on the product page
Reviews
There are no reviews yet.